Red-lion RLY6A Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Hardware Red-lion RLY6A herunter. Red Lion RLY6A User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 2
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
(100)
3.94
(60)
2.36
21
1.73
(44)
.31 (8)
Control
4-32 VDC
MADE IN U.S.A.
RED LION CONTROLS
RLY6A000
40 Amp
Output
24-660 VAC
SOLID STATE RELAY
YORK, PA.
4
-
M3058X
(87)
3.43
3
+
3.15
(80)
INTEGRATED HEAT SINK
OPTICALLY ISOLATED
SOLID STATE SWITCHING
SINGLE PHASE OUTPUT RATING: 25 A (RLY6) or 40 A (RLY6A)
SWITCHING: 24 TO 660 VAC
CONTROL SIGNAL: 4 TO 32 VDC
ZERO VOLTAGE TURN-ON
MOUNTS ON DIN RAIL OR DIRECTLY TO PANEL
4000 VOLT ISOLATION
BUILT-IN SNUBBER
LED “ON” INDICATOR
CAGE CLAMP TERMINATIONS
SAFETY SUMMARY
All safety related regulations, local codes and instructions
that appear in the literature or on equipment must be observed
to ensure personal safety and to prevent damage to either the
instrument or equipment connected to it. If equipment is used
in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
Do not use this unit to directly command motors, valves, or
other actuators not equipped with safeguards. To do so, can be
potentially harmful to persons or equipment in the event of a
fault to the unit.
MODEL RLY6/RLY6A - SINGLE PHASE DIN RAIL MOUNT SOLID STATE RELAY
Bulletin No. RLY6-E
Drawing No. LP0471
Released 04/13
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
1.18
(30)
3.94
(100)
RLY60000
2
25 Amp
Output
1
48-660 VAC
M2447B
-
4
SOLID STATE RELAY
RED LION CONTROLS
MADE IN U.S.A.YORK, PA.
3
Control
4-28 VDC
+
(87)
3.43
.71 (18)
3.15
(80)
.26 (6)
RLY6, 25 Amp DIMENSIONS In inches (mm)
TOP VIEW
GENERAL DESCRIPTION
The RLY60000 is a solid state relay that switches load currents up to 25 A; the RLY6A000
switches load currents up to 40 A. These units feature a zero voltage turn-on detector to minimize
radiated RFI when switching. An internal snubber guards against false triggering of the output
related to high dv/dt applications. A low level DC control signal of 4 to 32 VDC is all that is needed
for the switching operation. These units, highlighted by the inverse-parallel SCR output, provide a
greatly increased operational life over mechanical relays by avoiding the usual relay contact
problems such as: arcing, bouncing, and mechanical failure.
The RLY6/RLY6A can be directly controlled by logic/SSR drive output or sourcing output of
Red Lion Controls products.
UL Recognized Component,
File #E191578
R
LR 702877
CAUTION: Risk of Danger.
Read complete instructions prior to installation
and operation of the unit.
CAUTION: Risk of electric shock.
RLY6A, 40 Amp DIMENSIONS In inches (mm)
TOP VIEW
SPECIFICATIONS
OUTPUT SPECIFICATIONS
1. OPERATING VOLTAGE RANGE: 24 to 660 VAC
2. OPERATING FREQUENCY RANGE: 47 to 63 Hz
3. MAXIMUM CONTINUOUS LOAD CURRENT:
(See Safe Operating Conditions)
RLY6: 25 A
RMS
RLY6A: 40 A
RMS
4. SURGE CURRENT:
RLY6:
Non-Repetitive 1 Cycle: 250 A
PEAK
Non-Repetitive 1 Second: 100 A
PEAK
RLY6A:
Non-Repetitive 1 Cycle: 250 A
PEAK
Non-Repetitive 1 Second: 150 A
PEAK
5. MIN. LOAD CURRENT: 100 mA
6. LEAKAGE CURRENT @ V
OUT
(Max.): 8 mA
7. OVER VOLTAGE RATING: 1400 PIV
8. VOLTAGE DROP @ I
OUT
: 1.5 VAC
9. POWER DISSIPATION AT FULL LOAD:
RLY6: 25.0 Watts
RLY6A: 48.0 Watts
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - SPECIFICATIONS

(100)3.94(60)2.36211.73(44).31 (8)Control4-32 VDCMADE IN U.S.A.RED LION CONTROLSRLY6A00040 AmpOutput24-660 VACSOLID STATE RELAYYORK, PA.4-M3058X(87)3.

Seite 2 - RLY6A 40 A Derating Curve

SAFE OPERATING CONDITIONSThe relay must always operate within the “Safe Operating Area” of the Derating Curve Figure. Operations outside the Safe Oper

Verwandte Modelle: RLY6

Kommentare zu diesen Handbüchern

Keine Kommentare