1
z PID CONTROL WITH REDUCED OVERSHOOT
z UNIVERSAL PROCESS, TEMPERATURE, VOLTAGE, CURRENT
AND RESISTANCE INPUT
z PROGRAMMABLE DUAL LINE DISPLAY WITH UNITS
INDICATION AND BAR GRAPH
z FOUR PROGRAMMABLE UNIVERSAL ANNUNCIATORS
z TRI-COLOR DISPLAY, WITH 7 PROGRAMMABLE COLOR ZONES
z UP TO 16 ALARMS WITH BOOLEAN LOGIC FUNCTIONALITY
z BUILT-IN USB PROGRAMMING PORT ENABLING UNIT
CONFIGURATION WITH CRIMSON PROGRAMMING SOFTWARE
z NEMA 4X/IP65 SEALED FRONT BEZEL
DESCRIPTION
The PAX2C Temperature/Process Controller offers many features and
performance capabilities to suit a wide range of applications. The PAX2C has a
universal input to handle various input signals including Temperature, DC
Voltage/Current and Resistance. Optional plug-in cards allow the opportunity to
configure the controller for present applications, while providing easy upgrades
for future needs. The PAX2C employs a tri-color display with seven
independently programmable color zones.
The controller has been specifically designed for harsh industrial environments.
With NEMA 4X/IP65 sealed bezel, CE compliance and extensive testing of
noise effects, the controller provides a tough reliable application solution.
MAIN CONTROL
The controller operates in the PID Control Mode for both heating and cooling,
with on-demand auto-tune that establishes the tuning constants. The PID tuning
constants may be fine-tuned and then locked out from further modification. The
controller employs a unique overshoot suppression feature, that allows the
quickest response without excessive overshoot. Switching to Manual Mode
provides the operator direct control of the output.
DISPLAY
The PAX2C features a dual line display with units annunciators, dual bar
graphs, four universal annunciators and tri-color capability. Each of the seven
display zones may be configured independently of the others, providing a visual
indication of control and/or alarm status.
ALARMS
The PAX2C has up to sixteen “soft” alarms that may be configured to suit a
variety of control and alarm requirements. These alarms may be used to monitor
and/or actuate the controllers physical outputs as well as change display colors.
Mapped “soft” alarms may be processed independently or logically combined
using AND/OR Boolean logic.
OPTION CARDS
Optional plug-in cards provide dual FORM-C relays, quad FORM-A, quad
sinking, or quad sourcing open collector logic outputs. These cards can be used
as control outputs or for alarm indication.
A linear DC output signal is available as an optional plug-in card. The card
provides either 20 mA or 10 V signals. The output can be scaled independent of
the input range and can track the input, max and min readings or for control.
Communication and bus capabilities are also available as option cards. These
include RS232, RS485, DeviceNet, and ProfibusDP. The PAX2C can be
programmed to utilize Modbus protocol. With Modbus, the user has access to
most configuration parameters. Readout values, setpoint, process and alarm
values can be controlled through the bus. Additionally, the controller has a
feature that allows a remote computer to directly control the outputs of the
controller.
With a Windows
®
based program, made available by Red Lion Controls,
configuration data can be downloaded to the PAX2C via a built-in USB
programming port.
MODEL PAX2C – 1/8 DIN TEMPERATURE/PROCESS PID CONTROLLER
Bulletin No. PAX2C-B
Drawing No. LP0890
Released 04/13
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
3.80
1.95
0.10
4.14
(96.52)
(49.53)
(2.54)
(105.16)
1.75
(44.45)
3.60
(91.44)
Note: To determine dimensions for
horizontal units, swap height and
width. Recommended minimum
clearance (behind the panel) for
mounting clip installation is:
2.1" (53.4) W x 5.5" (140) H.
DIMENSIONS In inches (mm)
C
US LISTED
U
L
R
3RSD
PROCESS CONTROL EQUIPMENT
Seitenansicht 0
1 2 3 4 5 6 ... 55 56

Inhaltsverzeichnis

Seite 1 - DIMENSIONS In inches (mm)

1 z PID CONTROL WITH REDUCED OVERSHOOT z UNIVERSAL PROCESS, TEMPERATURE, VOLTAGE, CURRENT AND RESISTANCE INPUT z PROGRAMMABLE DUAL LINE DISPLAY WITH U

Seite 2 - Ordering infOrmaTiOn

106.0 prOgramming The paX2CThe PAX2C offers three display loops to allow users quick access to needed information.Main Display LoopIn the Main display

Seite 3 - Thermocouple Inputs:

11F1F2F1F2F1F2F1F2F1F2F1F2DPDP DAnalog Input SetupParametersUser Input/Function KeyParametersDDDFactory ServiceOperationsDisplay Loop2 secondsPro NOP

Seite 4 - LO/SINK HI/SOURCE

12inpuT parameTers (INPt)INPUT SELECTAnLG USErSelect the Input to be programmed.INPtP2CAnLGInputRangeInputScalingIce PointCompensationInputRateDisplay

Seite 5 - OpTiOnal plug-in Cards

13PROCESS INPUT TYPE250 uA 2 U 1k RES tc-r r3922.5 mA 10 U 10k RES tc-S r67225 mA 25 U tc-t tc-b r427250 mA 100 U tc-E tc-n2 A 200 U tc-J tc-C250 mU 1

Seite 6 - 2.0 seTTing The Jumpers

14Nonlinear - Scaling Points (Greater than 2)For non-linear processes, up to 16 scaling points may be used to provide a piece-wise linear approximatio

Seite 7 - 4.0 Wiring The COnTrOller

15F1F2PDPro NOProINPtINPtP2CUSErUSErP2CUACtUSErP2CUSr1USErP2CUSr2USErP2C F1USErP2C F2USErP2CSCF1USErP2CSCF2Function KeysUser InputsThe two user inp

Seite 8 - 4.1 POWER WIRING

16RESET MAXIMUM DISPLAYWhen activated (momentary action), rSEt flashes and the Maximum resets to the present Input Display value. The Maximum function

Seite 9 - 4.7 ANALOG OUTPUT WIRING

17OuTpuT parameTers (Out)OUTPUT SELECTdGtL AnLGSelect the Digital or Analog output to be programmed. The Analog output selection only appears if an an

Seite 10 - 6.0 prOgramming The paX2C

18AnalogOutput TypeAnalogOutputAssignmentAnalogLow ScaleValueAnalogHigh ScaleValueAnalogUpdateRateProbeBurn-outActionF1F2PDPro NOProOutOutP2CAnLGtYPE

Seite 11 - PROGRAMMING TIPS

19display parameTers (dISP)DisplayIntensityDisplayContrastDisplayRateMenuModeBasic ModeResetF1F2PDPro NOProdISPdISPCNFGdLEUdSP 4dCntdSP 7dSPtdSP

Seite 12 - This can be used

2Ordering Information ...2General Controller Specifications ...3Optional Plug-In Cards ...5Installing the Con

Seite 13 - DIGITAL FILTERING

20Line 1DisplayValueLine nDefaultColorLine nUnitsMnemonicLine nUnit 1MnemonicLine nUnit 2MnemonicLine nUnit 3MnemonicPDdISP2ONEF1F2PDPro NOProdISP2ON

Seite 14

21The following programming steps are only available in the Advanced Operating Mode.These parameters allow Line n backlights to change color, or alter

Seite 15 - Function KeysUser Inputs

22Univ Annun nDefault ColorUniv Annun nUnitsMnemonicPDdISP2ONEF1F2PDPro NOProdISP2ONEdSPUAnnColrUAn GrnUAnnUAn ONUniv Annun nUnit 1MnemonicUAn1UAn0U

Seite 16

23UNIVERSAL ANNUNCIATOR n GREEN BACKLIGHT ASSIGNMENTNONE Out1 Out2 Out3 Out4 ALr MANSelect the parameter to be used to activate the Green backlight o

Seite 17 - OuTpuT parameTers (Out)

24MnemonicsDefault ColorPDdISP2ONEF1F2PDPro NOProdISP2ONEdSP MnColrMn GrnAdvanced Menu Mode OnlyMnemonicsGreenBacklightAssignmentMnemonicsOrangeBackl

Seite 18 - (Temp Only)

25This section details programming for the Line 2 (Bottom Line) Display. Various Input, Display, PID, Alarm, and Function Parameters can be shown on t

Seite 19 - 1 2 5 10 20

26LINE 2 VALUE ACCESS PARAMETER SELECTIONINPt dISP Pid ALr FNCtSelect the display parameters to be displayed.LOCSLn2INPtLine 2Input ValueAccessPDdISPL

Seite 20 - = Line Number (1 or 2)

27Line 2Display LevelAccessPDdISPLOCSF1F2PDPro NOProdISPLOCSLn2dISPdLEULn2 LOCLine 2Display ContrastAccessdCntLn2 LOCdisplay parameTers: line 2 param

Seite 21

28Line 2Actual SetpointAccessPDdISPLOCSF1F2PDPro NOProdISPLOCSLn2 PidSPLn2 LOCLine 2Setpoint 1AccessSP1Ln2 LOCLine 2Setpoint 2AccessSP2Ln2 LOCLine 2O

Seite 22 - = UA Number (1 - 4)

29Line 2Alarm nAccessPDdISPLOCSF1F2PDPro NOProdISPLOCSLn2 ALrALnLn2 LOCLine 2Band nAccessbdnLn2 LOCdisplay parameTers: line 2 parameTer value aCCess

Seite 23

3general COnTrOller speCifiCaTiOns1. DISPLAY: Negative image LCD with tri-color backlight. The display is divided into seven independently programmabl

Seite 24

30MAX CaptureDelay TimeMIN CaptureDelay TimeF1F2PDPro NOProdISPdISPHILOHi-tSCN 1.0SECLO-tSCN 1.0SECdisplay parameTers: display min/maX COnfiguraTiO

Seite 25 - LINE 2 PARAMETER VALUE ACCESS

31pid parameTers (Pid)ControlTypeControlModeManual OutputPowerF1F2PDPro NOProPidPidCtrLtYPEHEAttrnFAutoOPUSr 0.0pid parameTers: COnTrOl parameTers (

Seite 26

32SetpointSelectionSetpoint 1ValueSetpoint 2ValueF1F2PDPro NOProPidPid SPSPSL SP1SP1 0.0 °FSP2 0.0 °FSetpointLow LimitSPLO 0.0 °FSetpointHigh Lim

Seite 27 - LINE 2 DISPLAY CONTRAST LEVEL

33PIDParameterSelectionPrimaryProportionalBand ValuePrimaryIntegralTime ValueF1F2PDPro NOProPidPid PidPid PriSELProP 4.0PriIntt 120PriPrimaryDerivat

Seite 28

34Fault ConditionPower ValueOutputDeadbandOutputHeat GainF1F2PDPro NOProPidPidPWrFLtP 50.0°/odEAd 0.0°/oHtGn100.0°/oHeat PowerLow LimitHtLo 0.0°/oH

Seite 29

35On/OffHysteresisOn/OffDeadbandF1F2PDPro NOProPidPidONOFHYSt 0.2 °F dEAd 0.0 °Fpid parameTers: On/Off parameTers (ONOF)ON/OFF HYSTERESIS0 to 50.0

Seite 30 - 0 to 250

36PID TuningCodePIDInitiate TuningF1F2PDPro NOProPidPidtunEtCdE 2 tunE N0pid parameTers: pid Tuning parameTers (tunE)PID TUNING CODE0 to 4 The Tu

Seite 31 - -100.0 to 100.0 %

37alarm parameTers (ALn)AlarmAssignmentAlarmActionAlarmValueAlarmBand/DeviationValueAlarmHysteresisValueOn TimeDelayOff TimeDelayAlarmLogicF1F2PDPro

Seite 32

38ALARM VALUE-1999 to 9999 Enter desired alarm value. Alarm values can also be entered when the alarm is programmed as dEnt, PEnt or HEnt. The decima

Seite 33

39pOrT parameTers (Port)PORT PARAMETER MENU SELECTIONUSb SErLSelect the Communication Port Mode.PortSRLUSbusb pOrT parameTers (USb)USBSetupF1F2PDPro

Seite 34

4 7. EXCITATION POWER: Jumper selectableTransmitter Power: +18 VDC, ± 5% @ 50 mA max.Reference Voltage: + 2 VDC, ± 2%Compliance: 1KW load min (2 mA ma

Seite 35 - -199.9 to 999.9 units

40METER UNIT ADDRESS0 to 99 = RLC Protocol1 to 247= ModbusSelect a Unit Address that does not match an address number of any other equipment on the se

Seite 36 - } Advanced Mode

41USBThe USB programming port is primarily intended to be used to configure the PAX2 with the Crimson programming software. It can also be used as a v

Seite 37 - NO AbHI AbLO AUHI AULO

42PAX2C FREQUENTLY USED MODBUS REGISTERSOnly frequently used registers are shown below. The entire Modbus Register Table can be found at www.redlion.n

Seite 38

43SERIAL RLC PROTOCOL COMMUNICATIONSRLC Communications requires the Serial Communications Type Parameter (tYPE) be set to “rLC”.SENDING SERIAL COMMAND

Seite 39 - OrT parameTers (Port)

44RECEIVING DATA FROM THE CONTROLLERData is transmitted by the controller in response to either a transmit command (T), a print block command (P) or U

Seite 40 - 0.000 to 0.250 seconds

45COMMUNICATION FORMATData is transferred from the controller through a serial communication channel. In serial communications, the voltage is switche

Seite 41 - SERIAL MODBUS COMMUNICATIONS

46faCTOry serviCe OperaTiOns (FACt)RESTORE FACTORY DEFAULTSUse the ! and @ keys to display COdE 66 and press P. The controller will flash rSEt and the

Seite 42

47Preparation for TC calibrationTC calibration parameters will affect RTD calibration. If using an RTD, it is recommended that the RTD calibration be

Seite 43

48OperaTiOn OvervieWCONTROLLER POWER-UPUpon applying power, the controller delays control action and temperature indication for several seconds to per

Seite 44

49PID CONTROLIn PID Control, the controller processes the input and then calculates a control output power value by use of a specialized Proportional

Seite 45 - Timing Diagrams

5WARNING: Disconnect all power to the unit before installing plug-in cards.Adding Option CardsThe PAX2C controllers can be fitted with up to three opt

Seite 46 - NO Curr UoLt rES

50AUTO-TUNEAuto-Tune is a user-initiated function where the controller automatically determines the Proportional Band, Integral Time, Derivative Time,

Seite 47 - OFSt) is set to 0

51AUTO-TUNE PROGRESSThe controller will oscillate the controlling output(s) for four phases. The bottom display will flash the phase number. Parameter

Seite 48 - COnTrOl mOde eXplanaTiOns

52TROUBLESHOOTING GUIDEPROBLEM REMEDIESNo Display At Power-Up Check power level and power connectionsNo Display After Power-UpCheck dLEU and dCnt prog

Seite 52 - TROUBLESHOOTING GUIDE

LIMITED WARRANTYThe Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years from

Seite 53

61.0 insTalling The COnTrOller2.0 seTTing The JumpersInstallation The PAX2C meets NEMA 4X/IP65 requirements when properly installed. The unit is inte

Seite 54

7The plug-in cards are separately purchased optional cards that perform specific functions. These cards plug into the main circuit board of the contro

Seite 55

84.1 POWER WIRING12AC/DCAC/DC4.2 VOLTAGE/RESISTANCE/CURRENT INPUT SIGNAL WIRINGIMPORTANT: Before connecting signal wires, the Input Range Jumpers an

Seite 56 - LIMITED WARRANTY

94.4 USER INPUT WIRINGIf not using User Inputs, then skip this section. User Input terminal does not need to be wired in order to remain in the inact