Red-lion PAX2A Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Computerzubehör Red-lion PAX2A herunter. Red Lion PAX2A User Manual [de] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 4
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
1
3.80 (96.52)
(49.53)
(2.54)
(44.45)
3.60 (91.44)
4.14 (105)
1.95
0.10
1.75
1
3
2
4
PAX2A
1/8 DIN Analog Input Panel Meter
Installation Guide
DIMENSIONS In inches (mm)
Note: Recommended minimum clearance (behind the panel) for mounting clip
installation is 2.1" (53.4) H x 5.5" (140) W.
See the Red Lion website at www.redlion.net or the enclosed
USB thumbdrive for a complete user manual
SPECIFICATIONS
POWER:
AC Power: 40 to 250 VAC, 50/60 Hz, 20 VA
DC Power: 21.6 to 250 VDC, 8 W
Isolation: 2300 Vrms for 1 min. to all inputs and outputs.
INPUT CAPABILITIES:
Current Input Ranges:
± 250 µADC ± 2.5 mADC ± 25 mADC
± 250 mADC ± 2 ADC
Voltage Input Ranges:
± 250 mVDC ± 2.0 VDC ± 10 VDC
± 25 VDC ± 100 VDC ± 200 VDC
Thermocouple Inputs:
Types: T, E, J, K, R, S, B, N, C (W5/W26)
Max Continuous Overvoltage: 30 V
RTD Inputs:
Type: 3 or 4 wire, 2 wire can be compensated for lead wire resistance
Excitation current: 100 ohm range: 136.5 µA ±10%
10 ohm range: 2.05 mA ±10%
Max. continuous overload: 30 VDC
Input Type:
100 ohm Pt alpha = .00385 100 ohm Pt alpha = .00392
120 ohm Nickel alpha = .00672 10 ohm Copper alpha = .00427
Resistance Inputs:
Max. continuous overload: 30 VDC
INPUT RANGE COMPLIANCE
100 ohm 0.175 V
999 ohm 1.75 V
9999 ohm 17.5 V
EXCITATION POWER: Jumper selectable
Transmitter Power: +18 VDC, ± 5% @ 50 mA max.
Reference Voltage: + 2 VDC, ± 2%
Compliance: 1KW load min (2 mA max)
Temperature Coefficient: 40 ppm/ºC max.
Reference Current: 1.05 mADC, ± 2%
Compliance: 10 KW load max.
USER INPUTS: Two programmable user inputs
Max. Continuous Input: 30 VDC
Isolation To Sensor Input Common: Not isolated.
ENVIRONMENTAL CONDITIONS:
Operating Temperature Range: 0 to 50 °C
Storage Temperature Range: -40 to 60 °C
Vibration to IEC 68-2-6: Operational 5-150 Hz, 2 g
Shock to IEC 68-2-27: Operational 25 g (10 g relay)
Operating and Storage Humidity: 0 to 85% max. RH non-condensing
Altitude: Up to 2000 meters
CERTIFICATIONS AND COMPLIANCES:
CE Approved
EN 61326-1 Immunity to Industrial Locations
Emission CISPR 11 Class A
IEC/EN 61010-1
RoHS Compliant
UL Listed: File #E179259
Type 4X Indoor Enclosure rating (Face only)
IP65 Enclosure rating (Face only)
IP20 Enclosure rating (Rear of unit)
CONNECTIONS: High compression cage-clamp terminal block
Wire Strip Length: 0.3" (7.5 mm)
Wire Gauge Capacity: One 14 AWG (2.55 mm) solid,
two 18 AWG (1.02 mm) or four 20 AWG (0.61 mm)
CONSTRUCTION: This unit is rated NEMA 4X/IP65 for indoor use only.
IP20 Touch safe. Installation Category II, Pollution Degree 2. One piece
bezel/ case. Flame resistant. Synthetic rubber keypad. Panel gasket and
mounting clip included.
WEIGHT: 8 oz. (226.8 g)
Drawing No. LP0900A
Effective 04/13
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
C
US LISTED
U
L
R
3RSD
PROCESS CONTROL EQUIPMENT
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - Installation Guide

13.80 (96.52)(49.53)(2.54)(44.45)3.60 (91.44)4.14 (105)1.950.101.751324PAX2A 1/8 DIN Analog Input Panel MeterInstallation GuideDIMENSIONS In inches (

Seite 2 - REAR TERMINALS

2SAFETY SUMMARYAll safety related regulations, local codes and instructions that appear in this literature or on equipment must be observed to ensure

Seite 3 - INP COMM

3POWER WIRINGThe power supplied to the meter shall employ a 15 Amp UL approved circuit breaker for AC input and a 1 Amp, 250 V UL approved fuse for DC

Seite 4 - ORDERING INFORMATION

420 Willow Springs Circle | York, PA 17406 USA+1 (717) 767-6511 | [email protected] | www.redlion.netLIMITED WARRANTYThe Company warrants the pro

Kommentare zu diesen Handbüchern

Keine Kommentare