DESCRIPTION
The CUB7P is an 8-digit miniature programmable counter with large 0.35
inch (8.90 mm) high digits. It has an LCD read-out available in Positive Image
Reflective, Negative Image Transmissive with yellow/green backlighting, or red
backlighting. Backlight units require an external 9 to 28 VDC power supply.
The CUB7P versions operate from a signal voltage of 10 to 300 V (AC 50/60
Hz or DC).
The CUB7P1 has a programmable prescaler that can be set for any value
between 0.0001 and 1.9999. The decimal point position can be set anywhere
from 0 (no D.P.) to 0.000000 or no Leading Zero Blanking. Both the prescaler
and DP selection are accessed using the front panel PGM and RESET push
buttons. See Programming for details. Note that the count, prescaler and DP
values will be lost if the battery is removed. See BATTERY INSTALLATION
for additional information.
The CUB7P counters use a CMOS LSI chip, mounted on a gold-plated
substrate, that is electrically connected by ultrasonic wire-bonding. Proven
micro-electronic assembly and manufacturing techniques provide these units
with the reliability and dependability required for industrial service.
The CUB7P series is housed in a lightweight, high impact plastic case with a
clear viewing window. The sealed front panel with the silicone rubber buttons
meets NEMA 4X/IP65 specifications for wash-down and/or dusty
environments, when properly installed.
SAFETY SUMMARY
All instructions that appear in the bulletin or on equipment, all safety related
regulations, and all local codes must be observed to ensure personal safety and
to prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
CAUTION: Read complete
instructions prior to installation
and operation of the unit.
CAUTION: Risk of electric shock.
1
O 3 (8 Digit 0.35") LCD DISPLAY OPTIONS (Reflective, Red
Transmissive, Yellow/Green Transmissive. 9 to 28 VDC power
supply required for versions w/ LED backlighting)
O AVAILABLE VOLTAGE INPUTS (10 TO 300 VAC/DC)
O PRESCALER FROM 0.0001 TO 1.9999
O SELECTABLE DECIMAL POINTS
O REPLACEABLE INTERNAL LITHIUM BATTERY PROVIDES UP
TO 6 YEARS OF UNINTERRUPTED OPERATION (Battery Included)
O WIRE CONNECTIONS VIA SCREW CLAMP TYPE TERMINALS
O FRONT PANEL AND REMOTE RESET INPUT
O NEMA 4X/IP65 SEALED FRONT BEZEL
O BOTH FRONT PANEL PROGRAM AND RESET BUTTONS ARE
INDIVIDUALLY ENABLED
MODEL CUB7P - PROGRAMMABLE ELECTRONIC 8-DIGIT COUNTER
DIMENSIONS In inches (mm)
Note: Recommended minimum clearance (behind the panel) for mounting clip installation
is 2.1" (53.4) H x 5.5" (140) W.
PANEL CUT-OUT
Bulletin No. CUB7P-C
Drawing No. LP0441
Released 5/06
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
BNL10000
CUB7P120
CUB7P110
CUB7P100
PART NUMBER
Counter; Positive Image Reflective
Counter, w/Yel-Grn Backlighting
Counter; w/Red Backlighting
Replacement 3 V Lithium BatteryBNL
VOLTAGE
INPUT
*CUB7P
DESCRIPTIONMODEL NO.
* Battery is included with unit.
ORDERING INFORMATION
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - ORDERING INFORMATION

DESCRIPTIONThe CUB7P is an 8-digit miniature programmable counter with large 0.35inch (8.90 mm) high digits. It has an LCD read-out available in Posit

Seite 2 - EMC INSTALLATION GUIDELINES

2SPECIFICATIONS1. DISPLAY: 8-digit LCD, 0.35" (8.90 mm) high digits.2. POWER SOURCE: Replaceable Internal 3.0 V lithium battery to provide upto 6

Seite 3 - BATTERY INSTALLATION

3Ferrite Suppression Cores for signal and control cables:Fair-Rite # 0443167251 (RLC #FCOR0000)TDK # ZCAT3035-1330ASteward #28B2029-0A0Line Filters fo

Seite 4 - BACKLIGHT OPTION

4RESET AND PROGRAM OPTIONSConnecting a wire from the RST EN (Reset Enable) or the HS (ProgramEnable) Input terminals to Common will enable the front p