13.80 (96.52)(49.53)(2.54)(44.45)3.60 (91.44)4.14 (105)1.950.101.751324 z COUNT, DUAL COUNTER WITH MATH FUNCTIONS z RATE, DUAL RATE WITH MATH FUNCTION
10As an alternative, a Select and Set value entry method is provided. This can be used in combination with the value scrolling described above. To cha
11Counter B SelectionsSELECTION MODE DESCRIPTIONNONENone Does not count.bAtCHBatch Counter B internally counts the number of output activations of the
12SCALING CALCULATIONEach counter has the ability to scale an input signal to a desired display value. This is accomplished by the counter mode (Cnt x
13Non-linear Application – Up to 10 Scaling PointsFor non-linear processes, up to 10 scaling points may be used to provide a piece-wise linear approxi
14RATE C DISPLAY MULTIPLIER1 10 100 1000Set the Display Multiplier to obtain the desired Rate C display resolution. For Rate C percentage calculations
15USrACtLO USrUSEr-1NO USrUSEr-2NO USrF1SEL L1FNCF2NO FNCSEC-F1NO FNCSEC-F2NO FNCFunction KeysUser InputsINPUt USEr USEr-3NO USr ProINPUt Pro
16 SELECT PARAMETER LIST Two lists of values are available to allow the user to switch between two sets of Setpoints, Scale Factors, Counter Load valu
17OUtPUt SEtPNt SELECtS1 SPtSetpointSelectASSIGNNONE SnSetpointAssignmentLOGICNOr SnOutputLogicACtIONNO SnSetpointActionAnnunNOr SnSetpointAnnun
18SETPOINT SELECTS1 S2 S3 S4Select the Setpoint output to be programmed. The “Sn” in the following parameters will reflect the chosen setpoint number.
19HYSTERESIS VALUE0 to 59999The hysteresis value is added to (for tYPE = LO-ACt), or subtracted from (for tYPE = HI-ACt), the setpoint value to determ
2Ordering Information ...2General Meter Specifications ...3Optional Plug-In Cards ...4Installing the Meter
20ANALOG OUTPUT TYPE4-20 0-10 0-20Enter the analog output type. For 0-20 mA or 4-20 mA use terminals 18 and 19. For 0-10 V use terminals 16 and 17. On
21LINE 1 DISPLAY COLORGrEEN rEd OrANGEEnter the desired Display Line 1 and programmable Units Display color.DISPLAY INTENSITY LEVEL1 to 4Enter the des
22LINE 2 VALUE ACCESSNO YESSelect YES to program the Value Access setting for each available Line 2 parameter. Line 2 values can be made accessible i
23LINE 2 DISPLAY SCROLL ENABLE/TIMENO 1 to 15 secondsIf Line 2 Display Scrolling is desired, set the scroll time in seconds.LINE 2 UNITS MNEMONIC(S)OF
24COMMUNICATIONS TYPEMbrtu - Modbus RTUMbASC - Modbus ASCIIrLC - RLC Protocol (ASCII)Select the desired communications protocol. Modbus is preferr
25USBThe USB programming port is primarily intended to be used to configure the PAX2D with the Crimson programming software. It can also be used as a
26REGISTER ADDRESSREGISTER NAME LOW LIMIT HIGH LIMITFACTORY SETTINGACCESS COMMENTSFREQUENTLY USED REGISTERS40001 Counter A Value (Hi word)-199999999
27RLC Communications requires the Serial Communications Type Parameter (tYPE) be set to rLC.SENDING SERIAL COMMANDS AND DATA TO THE METERWhen sending
28Abbreviated Transmission (Numeric data only)Byte Description1-12 12 byte data field, 10 bytes for number, one byte for sign, one byte for deci
29COMMUNICATION FORMATData is transferred from the meter through a serial communication channel. In serial communications, the voltage is switched bet
3general meTer speCifiCaTiOns1. DISPLAY: Negative image LCDTop Line - 6 digit, 0.71" (18 mm), with tri-color backlight (red, green or orange), di
30faCTOry serviCe OperaTiOns (FACtrY)FACTORY SERVICE CODE0-250Enter the Service Code for the desired operation.RESTORE FACTORY DEFAULTSUse the ! and @
31TROUBLESHOOTINGPROBLEM REMEDIESNo Display At Power-Up Check power level and power connections.No Display After Power-UpCheck Display Module: d-LEU,
32OUtPUt OUTPUT PARAMETERSSEtPNt Setpoint Output ParametersDISPLAY PARAMETER USER SETTING USER SETTING USER SETTING USER SETTINGSELECtSetpoint Se
33dISPLY DISPLAY PARAMETERSLINE 1 Line 1 ParametersDISPLAY PARAMETER USER SETTINGColorLine 1 Display Colord-LEVDisplay Leveld-ContDisplay Contras
34paX2d prOgramming QuiCK OverviewtYPE4-20 AnLASSIGNNONE AnLLO-SCL0AnLHI-SCL10000AnLAnalogOutput TypeAnalog OutputAssignmentAnalog LowScale ValueAnalo
35tYPE4-20 AnLASSIGNNONE AnLLO-SCL0AnLHI-SCL10000AnLAnalogOutput TypeAnalog OutputAssignmentAnalog LowScale ValueAnalog HighScale Value ProPort Port
LIMITED WARRANTYThe Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years from
4WARNING: Disconnect all power to the unit before installing plug-in cards.Adding Option CardsThe PAX2D meters can be fitted with up to three optional
51.0 insTalling The meTer2.0 seTTing The dip swiTChesInstallation The PAX2D meets NEMA 4X/IP65 requirements when properly installed. The unit is inte
6The plug-in cards are separately purchased optional cards that perform specific functions. These cards plug into the main circuit board of the meter.
74.1 POWER WIRING12AC/DCAC/DC4.2 INPUT SIGNAL WIRING12AC/DCAC/DC+-12AC/DCAC/DC+-ORAC PowerDC PowerCAUTION: Sensor input common is NOT isolated from
84.3 USER INPUT WIRING If User Input 1 and/or 2 are wired for quadrature or directional counting, an additional switching device should not be connec
9The PAX2D offers three display loops to allow users quick access to needed information.Main Display LoopIn the Main display loop, the D key is presse